The UPS3000 LTD3000 series three-in, three-out integrated power distribution integrates UPS power supply, IT power distribution, air conditioning power distribution, lighting power distribution, ATS power supply, UPS input, UPS output, UPS bypass, and UPS maintenance bypass power distribution into a power distribution cabinet through a combination of technical means, realizing the safety, reliability, easy maintenance, and high integration density of the power supply and distribution system, and providing a safe, reliable, stable, and efficient green power supply system for the data center.
Product Introduction
The UPS3000+LTD3000 series three-in, three-out integrated power distribution integrates UPS power supply, IT power distribution, air conditioning power distribution, lighting power distribution, ATS power supply, UPS input, UPS output, UPS bypass, and UPS maintenance bypass power distribution into a power distribution cabinet through a combination of technical means, realizing the safety, reliability, easy maintenance, and high integration density of the power supply and distribution system, and providing a safe, reliable, stable, and efficient green power supply system for the data center.
Specifications
Cabinet capacity: 20~180KVA Rated voltage: 220, 230, 240VAC Rated frequency: 50/60HZ self-adaptive
Input mode: single input/dual ATS switching input
Power distribution specifications: the main circuit supports 630A,
Supports 48 IT outputs,
Support 8 air conditioning outputs, 3 lighting outputs
Module capacity: 20/30/50KVA, Output power factor: 1 Inverter efficiency: 96%
Number of battery cells: 30-50 cells adjustable
Function Description
Standard C-level lightning protection design, up and down can enter and exit the line.
Support optional 20/30/50KVA module.
7-inch color touch man-machine interface, real-time recording of UPS and power distribution working status and operation information.
Dual-input and single-input power supply modes are optional.
Intelligent monitoring of power distribution, which can realize the monitoring of UPS operation status and module operating parameters, distribution mains, branch status, electrical parameters, etc.
The control module adopts 1+1 redundant hot-swappable monitoring module.
The distribution circuit breakers can be selected from Schneider and ABB brands, and the IT feeder branch and the air conditioning distribution branch can be configured according to the actual needs of the site to meet the personalized customization requirements of customers.
The high-density design of the power module makes the UPS power density higher and the cabinet size smaller, with 20/30 power modules using 2U height and 50K power modules using 3U height.
Support CAN, RS485, SNMP, RS232, dry contact and other communication methods to meet different customer needs.